gamepad_get_button_threshold(device);
Argument | Description |
---|---|
device | Which gamepad device "slot" to check. |
Returns: Real
This function can be used to detect the current threshold
setting of the analogue buttons for a given device. The default
threshold for all analogue buttons is 0.5, with the range being
from 0 to 1. The threshold defines at what point the button is
considered as being "pressed" for games that require them to act as
a digital button.
if gamepad_get_button_threshold(0) != 0.5
{
gamepad_set_button_threshold(0, 0.5);
}